Secondary Barricade situations arise when the Staff key is unable to operate the lock cylinder. Should this situation arise the PR-2 secondary override facility is accessed as follows;
The lock case incorporates a deadlock with a push/pull roller catch. The deadbolt is thrown or withdrawn either by the anti-ligature thumb turn / pull on the inside and by the key in the single cylinder on the outside...
The lock case incorporates a bathroom deadlock with a push/pull roller catch. The deadbolt is thrown or withdrawn by the anti-ligature thumb turn / pull on the inside which at the same time changes the room status indicator on the outside. The deadbolt is thrown and withdrawn from the outside by use of the key in the single cylinder...
The deadlocking night latch will automatically deadlock when the door is closed. A 20 degree turn of the internal anti-ligature thumb turn releases the latch allowing the door to be pulled open by way of the integral anti-ligature pull. Externally the door is unlocked by use of the key...
This lock set helps provide an anti-ligature solution by combining a roller bolt deadlock with anti-ligature pull handles.
In day to day use, the door can be held closed by the adjustable roller bolt. If however it is necessary to "lock off" the room, this is done by use of the staff control key in the external cylinder...
The lock set combines an auto deadlocking night latch with anti-ligature pull handles.
In day to day use, the door is automatically locked when closed and can be opened by the staff control key from both sides. A holdback facility can be provided if required...
This lock set is designed for use on single or double action doors where key access is required from both sides.
The lock set combines a roller bolt deadlock with pull handles both sides. The door can be held closed (not locked) on the roller bolt if required...
Note 1 - The term ‘Anti-Ligature’ is used to indicate that a product has been designed to limit the potential for a ligature to be fastened to it. It does not signify that the product is completely ligature proof. Please see Standards & Testing.
Note 2 - Standard Primera products are designed for internal applications only. For external applcations products plated to ‘Service Condition 5’ should be requested/specified.